سنسور القایی (Inductive sensor) PEPEERL+ FUCHS
سنسور القایی یا ( سنسور الکترومغناطیسی) ،درواقع نوعی سنسور بدون تماس می باشد که فقط دربرابر فلزات عمل کرده و در نهایت سیگنال های مورد نیاز را ایجاد و فرمان های لازم را به سایر قطعات میدهد.
Normally open (NO)
Switching function
PNP
Output type
0.6 mm
Rated operating distance
flush
Installation
DC
Output polarity
0...0.486mm
Assured operating distance
0.4
Reduction factor rAl
0.29
Reduction factor rCu
0.76
Reduction factor r304
0.46
Reduction factor rBrass
3-wire
Output type
10 ... 30 V
Operating voltage
0 ... 1400 Hz
Switching frequency
typ. 5%
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
0 ... 0 100 mA
Operating current
0 ... 0.1 mA typ. at 25 °C
Off-state current
≤ 10 mA
No-load supply current
LED, yellow
Switching state indicator
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
PNP
Output type
0.6 mm
Rated operating distance
flush
Installation
DC
Output polarity
0...0.486mm
Assured operating distance
0.4
Reduction factor rAl
0.29
Reduction factor rCu
0.76
Reduction factor r304
0.46
Reduction factor rBrass
3-wire
Output type
10 ... 30 V
Operating voltage
0 ... 1400 Hz
Switching frequency
typ. 5%
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
0 ... 0 100 mA
Operating current
0 ... 0.1 mA typ. at 25 °C
Off-state current
≤ 10 mA
No-load supply current
LED, yellow
Switching state indicator
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Normally open (NO)
Switching function
PNP
Output type
0.8 mm
Rated operating distance
flush
Installation
DC
Output polarity
0...0.648mm
Assured operating distance
0.45
Reduction factor rAl
0.4
Reduction factor rCu
0.77
Reduction factor r304
3-wire
Output type
10 ... 30 V
Operating voltage
0 ... 3000 Hz
Switching frequency
typ. 5%
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
Operating current
0 ... 0.1 mA typ. 0.1 µA at 25 °C
Off-state current
≤ 10 mA
No-load supply current
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1400 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
PNP
Output type
0.8 mm
Rated operating distance
flush
Installation
DC
Output polarity
0...0.648mm
Assured operating distance
0.45
Reduction factor rAl
0.4
Reduction factor rCu
0.77
Reduction factor r304
3-wire
Output type
10 ... 30 V
Operating voltage
0 ... 3000 Hz
Switching frequency
typ. 5%
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
Operating current
0 ... 0.1 mA typ. 0.1 µA at 25 °C
Off-state current
≤ 10 mA
No-load supply current
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1400 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
PNP
Output type
0.8 mm
Rated operating distance
flush
Installation
DC
Output polarity
0...0.648mm
Assured operating distance
0.45
Reduction factor rAl
0.4
Reduction factor rCu
0.85
Reduction factor r304
3-wire
Output type
10 ... 30 V
Operating voltage
0 ... 3000 Hz
Switching frequency
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
Operating current
0 ... 0.1mA
Off-state current
≤ 15 mA
No-load supply current
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1402 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
PNP
Output type
0.8 mm
Rated operating distance
flush
Installation
DC
Output polarity
0...0.648mm
Assured operating distance
mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
5 mm x 5 mm x 1 mm
Actuating element
0.6
Reduction factor rAl
0.45
Reduction factor rCu
0.85
Reduction factor r304
0.6
Reduction factor rBrass
3-wire
Output type
10 ... 30 V DC
Operating voltage
0 ... 10000Hz
Switching frequency
0.01 ... 0.1
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
yes
Overload resistance
yes
Wire breakage protection
yes
Inductive overvoltage protection
yes
Surge suppression
≤ 10 %
Ripple
≤ 1.5 V
Voltage drop
0.01 mm
Repeat accuracy
0 ... 200 mA
Operating current
0 ... 0.1 mA
Off-state current
≤ 5 mA
No-load supply current
≤ 1 ms
Time delay before availability
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1354 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
PNP
Output type
1.5 mm
Rated operating distance
flush
Installation
DC
Output polarity
0 ... 1.215 mm
Assured operating distance
5 mm x 5 mm x 1 mm
Actuating element
0.41
Reduction factor rAl
0.38
Reduction factor rCu
0.85
Reduction factor r304
0.54
Reduction factor rBrass
3-wire
Output type
10 ... 30 V
Operating voltage
0 ... 3000 Hz
Switching frequency
1 ... 15%
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
0 ... 200 mA
Operating current
0 ... 0.1 mA typ. 0.1 µA at 25 °C
Off-state current
≤ 10 mA
No-load supply current
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1245 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
Two-wire
Output type
1.5 mm
Rated operating distance
flush
Installation
DC
Output polarity
0 ... 1.21 mm
Assured operating distance
Actual operating distance
0.22
Reduction factor rAl
0.16
Reduction factor rCu
0.64
Reduction factor r304
2-wire
Output type
5 ... 60 V
Operating voltage
0 ... 1200 Hz
Switching frequency
1 ... 10 typ. 5 %
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 5 V
Voltage drop
2 ... 100 mA
Operating current
2 mA
Lowest operating current
0 ... 0.5 mA typ.
Off-state current
≤
Time delay before availability
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1476 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
Certified by China Compulsory Certification (CCC)
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
PNP
Output type
0.5 mm
Rated operating distance
flush
Installation
DC
Output polarity
Assured operating distance
0.45
Reduction factor rAl
0.35
Reduction factor rCu
0.75
Reduction factor r304
3-wire
Output type
10 ... 30 V DC
Operating voltage
0 ... 1500 Hz
Switching frequency
typ. 3 %
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
0 ... 100 mA
Operating current
0 ... 0.5 mA typ.
Off-state current
≤ 15 mA
No-load supply current
≤ 20 ms
Time delay before availability
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1528 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
cCSAus Listed, General Purpose
CSA approval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature
Normally open (NO)
Switching function
PNP
Output type
1.5 mm
Rated operating distance
flush
Installation
DC
Output polarity
0 ... 1.215 mm
Assured operating distance
0.45
Reduction factor rAl
0.35
Reduction factor rCu
0.75
Reduction factor r304
3-wire
Output type
10 ... 30 V DC
Operating voltage
0 ... 1500 Hz
Switching frequency
typ. 3 %
Hysteresis
reverse polarity protected
Reverse polarity protection
pulsing
Short-circuit protection
≤ 3 V
Voltage drop
0 ... 100 mA
Operating current
0 ... 0.5 mA typ.
Off-state current
≤ 15 mA
No-load supply current
≤ 20 ms
Time delay before availability
LED, yellow
Switching state indicator
Functional safety related parameters
MTTFd
1528 a
Mission Time (TM )
20 a
Diagnostic Coverage (DC)
0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose
ULapproval
cCSAus Listed, General Purpose
CSA approval
CCC approval / marking not required for products rated ≤36 V
CCC approval
-25 ... 70 °C (-13 ... 158 °F)
Ambient temperature