سنسور القایی (Inductive sensor) PEPEERL+ FUCHS

سنسور القایی یا ( سنسور الکترومغناطیسی) ،درواقع نوعی سنسور بدون تماس می باشد که فقط دربرابر فلزات عمل کرده و در نهایت سیگنال های مورد نیاز را ایجاد و فرمان های لازم را به سایر قطعات میدهد.

General specifications
Normally open (NO) Switching function
PNP Output type
0.6 mm Rated operating distance
flush Installation
DC Output polarity
0...0.486mm Assured operating distance
0.4 Reduction factor rAl
0.29 Reduction factor rCu
0.76 Reduction factor r304
0.46 Reduction factor rBrass
3-wire Output type
Nominal ratings
10 ... 30 V Operating voltage
0 ... 1400 Hz Switching frequency
typ. 5% Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0 ... 0 100 mA Operating current
0 ... 0.1 mA typ. at 25 °C Off-state current
≤ 10 mA No-load supply current
LED, yellow Switching state indicator
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature

NBB0,6-4GM22-E2

General specifications
Normally open (NO) Switching function
PNP Output type
0.6 mm Rated operating distance
flush Installation
DC Output polarity
0...0.486mm Assured operating distance
0.4 Reduction factor rAl
0.29 Reduction factor rCu
0.76 Reduction factor r304
0.46 Reduction factor rBrass
3-wire Output type
Nominal ratings
10 ... 30 V Operating voltage
0 ... 1400 Hz Switching frequency
typ. 5% Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0 ... 0 100 mA Operating current
0 ... 0.1 mA typ. at 25 °C Off-state current
≤ 10 mA No-load supply current
LED, yellow Switching state indicator
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F)

General specifications
Normally open (NO) Switching function
PNP Output type
0.8 mm Rated operating distance
flush Installation
DC Output polarity
0...0.648mm Assured operating distance
0.45 Reduction factor rAl
0.4 Reduction factor rCu
0.77 Reduction factor r304
3-wire Output type
Nominal ratings
10 ... 30 V Operating voltage
0 ... 3000 Hz Switching frequency
typ. 5% Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0 ... 200 mA
Operating current
0 ... 0.1 mA typ. 0.1 µA at 25 °C Off-state current
≤ 10 mA No-load supply current
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1400 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature

General specifications
Normally open (NO) Switching function
PNP Output type
0.8 mm Rated operating distance
flush Installation
DC Output polarity
0...0.648mm Assured operating distance
0.45 Reduction factor rAl
0.4 Reduction factor rCu
0.77 Reduction factor r304
3-wire Output type
Nominal ratings
10 ... 30 V Operating voltage
0 ... 3000 Hz Switching frequency
typ. 5% Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0 ... 200 mA
Operating current
0 ... 0.1 mA typ. 0.1 µA at 25 °C Off-state current
≤ 10 mA No-load supply current
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1400 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature

General specifications
Normally open (NO) Switching function
PNP Output type
0.8 mm Rated operating distance
flush Installation
DC Output polarity
0...0.648mm Assured operating distance
0.45 Reduction factor rAl
0.4 Reduction factor rCu
0.85 Reduction factor r304
3-wire Output type
Nominal ratings
10 ... 30 V Operating voltage
0 ... 3000 Hz Switching frequency
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0.1 ...100 mA
Operating current
0 ... 0.1mA Off-state current
≤ 15 mA No-load supply current
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1402 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature
General specifications
Normally open (NO) Switching function
PNP Output type
0.8 mm Rated operating distance
flush Installation
DC Output polarity
0...0.648mm   Assured operating distance
mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
5 mm x 5 mm x 1 mm
Actuating element
0.6 Reduction factor rAl
0.45 Reduction factor rCu
0.85 Reduction factor r304
0.6 Reduction factor rBrass
3-wire Output type
Nominal ratings
10 ... 30 V DC Operating voltage
0 ... 10000Hz Switching frequency
0.01 ... 0.1 Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
yes Overload resistance
yes Wire breakage protection
yes Inductive overvoltage protection
yes Surge suppression
≤ 10 % Ripple
≤ 1.5 V Voltage drop
0.01 mm Repeat accuracy
0 ... 200 mA Operating current
0 ... 0.1 mA Off-state current
≤ 5 mA No-load supply current
≤ 1 ms Time delay before availability
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1354 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature
General specifications
Normally open (NO) Switching function
PNP Output type
1.5 mm Rated operating distance
flush Installation
DC Output polarity
0 ... 1.215 mm   Assured operating distance
5 mm x 5 mm x 1 mm Actuating element
0.41 Reduction factor rAl
0.38 Reduction factor rCu
0.85 Reduction factor r304
0.54 Reduction factor rBrass
3-wire Output type
Nominal ratings
10 ... 30 V Operating voltage
0 ... 3000 Hz Switching frequency
1 ... 15% Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0 ... 200 mA Operating current
0 ... 0.1 mA typ. 0.1 µA at 25 °C Off-state current
≤ 10 mA No-load supply current
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1245 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature
General specifications
Normally open (NO) Switching function
Two-wire Output type
1.5 mm Rated operating distance
flush Installation
DC Output polarity
0 ... 1.21 mm   Assured operating distance
1.35 ... 1.65 mm typ.
Actual operating distance
0.22 Reduction factor rAl
0.16 Reduction factor rCu
0.64 Reduction factor r304
2-wire Output type
Nominal ratings
5 ... 60 V Operating voltage
0 ... 1200 Hz Switching frequency
1 ... 10 typ. 5 % Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 5 V Voltage drop
2 ... 100 mA Operating current
2 mA Lowest operating current
0 ... 0.5 mA typ. Off-state current
 ≤ Time delay before availability
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1476 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
Certified by China Compulsory Certification (CCC) CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature
General specifications
Normally open (NO) Switching function
PNP Output type
0.5 mm Rated operating distance
flush Installation
DC Output polarity
0 ... 1.215 mm
Assured operating distance
0.45 Reduction factor rAl
0.35 Reduction factor rCu
0.75 Reduction factor r304
3-wire Output type
Nominal ratings
10 ... 30 V DC Operating voltage
0 ... 1500 Hz Switching frequency
typ. 3 % Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0 ... 100 mA Operating current
0 ... 0.5 mA typ. Off-state current
≤ 15 mA No-load supply current
≤ 20 ms Time delay before availability
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1528 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
cCSAus Listed, General Purpose
CSA approval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature
General specifications
Normally open (NO) Switching function
PNP Output type
1.5 mm Rated operating distance
flush Installation
DC Output polarity
0 ... 1.215 mm Assured operating distance
0.45 Reduction factor rAl
0.35 Reduction factor rCu
0.75 Reduction factor r304
3-wire Output type
Nominal ratings
10 ... 30 V DC Operating voltage
0 ... 1500 Hz Switching frequency
typ. 3 % Hysteresis
reverse polarity protected Reverse polarity protection
pulsing Short-circuit protection
≤ 3 V Voltage drop
0 ... 100 mA Operating current
0 ... 0.5 mA typ. Off-state current
≤ 15 mA No-load supply current
≤ 20 ms Time delay before availability
LED, yellow Switching state indicator
Functional safety related parameters
MTTFd 1528 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
EN 60947-5-2:2007
IEC 60947-5-2:2007
Standards
Approvals and certificates
cULus Listed , General Purpose          ULapproval
cCSAus Listed, General Purpose
CSA approval
CCC approval / marking not required for products rated ≤36 V CCC approval
Ambient conditions
-25 ... 70 °C (-13 ... 158 °F) Ambient temperature